Advertisement

On a new multi-source X-ray tube concept for minimizing imaging time in digital breast tomosynthesis

      Abstract

      Replacing moving mechanics in computed tomography (CT) and digital breast tomosynthesis (DBT) has inspired numerous projects to develop alternative X-ray sources. While less suitable for CT, DBT is a viable target application for the multi-X-ray-source array tube suggested in Becker, A.E., et al. (2020): A prototype Multi-X-ray-source array (MXA) for digital breast tomosynthesis. Physics in Medicine & Biology, 65(23), 235033. The proposed prototype MXA tube comprises rotating anode disks and a set of thermionic grid switchable cathodes. It is a first-of-a-kind X-ray tube emitting brake radiation (Bremsstrahlung), developed to minimize exposure times for DBT down to the limits set by the dynamics of the employed flat panel detectors. This commentary takes a closer look at the above article and the presented concept. The MXA is expected to be scalable for long service life. The technology has potential for further extension beyond the primary target application of mammography tomosynthesis.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Physica Medica: European Journal of Medical Physics
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Becker A.E.
        • Hernandez A.M.
        • Boone J.M.
        • Schwoebel P.R.
        A prototype Multi-X-ray-source array (MXA) for digital breast tomosynthesis.
        Phys Med Biol. 2020; 65235033
      1. Behling R. Cathodes of medical X-ray tubes, in Modern developments in vacuum electron sources, 1st ed., Springer International Publishing AG, Basel, Switzerland, 2020, pp. XVIII, 599.

      2. Behling R. Modern Diagnostic X-Ray Sources, CRC Press, Boca Raton, FL, USA; 2015.

        • Behling R.
        Modern diagnostic X-ray sources - technology-manufacturing-reliability. 2nd ed. CRC Press, Taylor and Francis, LLC, Boca Rayton, FL, USA2021
        • Baek J.
        • De Man B.
        • Harrison D.
        • Pelc N.J.
        Raw data normalization for a multi source inverse geometry CT system.
        Opt Express. 2015; 23: 7514
        • Baek J.
        • De Man B.
        • Uribe J.
        • Longtin R.
        • Harrison D.
        • Reynolds J.
        • et al.
        A multi-source inverse-geometry CT system: initial results with an 8 spot x-ray source array.
        Phys Med Biol. 2014; 59: 1189-1202
        • Speidel M.A.
        • Wilfley B.P.
        • Star-Lack J.M.
        • Heanue J.A.
        • Van Lysel M.S.
        Scanning-beam digital x-ray (SBDX) technology for interventional and diagnostic cardiac angiography.
        Med Phys. 2006; 33: 2714-2727
        • Speidel M.A.
        • Tomkowiak M.T.
        • Raval A.N.
        • Van Lysel M.S.
        Three-dimensional tracking of cardiac catheters using an inverse geometry x-ray fluoroscopy system.
        Med Phys. 2010; 37: 6377-6389
        • Tomkowiak M.T.
        • Raval A.N.
        • Van Lysel M.S.
        • Funk T.
        • Speidel M.A.
        Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation.
        J Med Imaging. 2014; 1033504
      3. Dunkerley DAP, Funk T, Speidel MA. Method for dose-reduced 3D catheter tracking on a scanning-beam digital x-ray system using dynamic electronic collimation. 97831Y; 2016.

      4. Morgan H. Rotating anode x-ray tube with multiple simultaneously emitting focal spots. US6125167A, issued 2000; 2000.

      5. Ghono M, Hagiwara A. X-ray apparatus and X-ray tube. US7187756B2, issued 2007; 2007.

      6. Behling R. Multiple focal spot X-ray tube with multiple electron beam manipulating units. US7949102B2, issued 2011; 2011.

      7. Behling RKO, Foellmer MW. Multiple X-ray beam tube. US9767982B2, issued 2017; 2017.

      8. Boutchko R, Hsieh J, Mistretta C, Patch S. Computed tomography with z-axis scanning. US2005100126A1, issued 2005; 2005.

        • Shefer E.
        • Altman A.
        • Behling R.
        • Goshen R.
        • Gregorian L.
        • Roterman Y.
        • et al.
        State of the art of CT detectors and sources: a literature review.
        Curr Radiol Rep. 2013; 1: 76-91
      9. IEC 60336 (2020), 5th ed. – Electrical and loading characteristics of X-ray tube assemblies for medical diagnosis, International Electrotechnical Commission, Geneva, Switzerland.